Diagonal measure (cross measure)
Radian measure, width & length

Side, cut-out & mesh measures |
|
Standard tolerances for mesh gratings
This sheet of tolerances applies to pressure-locked gratings with the following specifications:
- Bearing bars 60 x 5 mm
- Mesh size max. 66 mm and min. 11 mm
- Grating size max. 2.0 m2, where one side measure does not exceed 2000 mm.
Diagonal measure (cross measure)
The difference between D1 and D2 must not exceed:± D1 - D2 0,012 x S where:
D1 : Diagonal measure 1
D2 : Diagonal measure 2
S : Largest side measure
|
Largest side measur |
Max. D1-D2 |
|
200 |
2,4 mm |
|
400 |
4,8 mm |
|
600 |
7,2 mm |
|
800 |
9,6 mm |
|
1000 |
12,0 mm |
|
1500 |
18,0 mm |
|
2000 |
24,0 mm |
Radian measure, width & length
For L/B > 450 mm: 1/150 x L/B, yet max. 8,0 mm
For L/B 450 mm: max. 3,0 mm
For L/B > 600 mm: 1/200 x L/B, dog max. 8,0 mm
For L/B 600 mm: max. 3,0 mm
Side, cut-out & mesh measures
L & B : +0 / -4 mm
d : ± 1,5 mm
d10 : ± 4,0 mm (over 10 meshes)
f, e, g, Ø : +8 / -0 mm
Smaller/other tolerances may be applied on request. |